Voltage Manual Controllers

Voltage Manual Controllers
Voltage Manual Controllers
Send Inquiry
Product Code : DES-9
Brand Name : MRM PROCOM PVT. LTD
Product Description

Manual Controllers

Protection, Supervision Salient features

  • Voltage monitoring and protection for under/over voltage and over speeding.
  • Emergency
  • Low Fuel
  • Oil Pressure
  • Charging Alternator Fail/V-Belt
  • HWT
  • Choice of selective sensor measurement display
  • RWL
  • Over Load

Measurement & Display

DES-9 equipped with LCD display and displays

  • Generator voltage
  • Fuel Level in %
  • Generator Frequency
  • Programmed settings
  • Generator Current
  • KW
  • Battery Voltage
  • PF
  • Generator Run Hour
  • KWhr
  • RPM
  • Service Hour
  • Oil Pressure in KG/cm2
  • Radiator Temp in degree centigrade


Normally the display auto scrolls and displays a set of parameter for 10 seconds, but any time the Next key (^) can be pressed to select the next parameter window.

Parameter Mode

Display

Explanation of parameter

Factory setting

Setting Range

Generator O/V

Max. permissible voltage, above this the voltage is treated unhealthy & the Generator is stopped.

270V

80-300 V

Generator U/V

Min. permissible voltage, below this the voltage is treated unhealthy & the Generator is stopped.

180V

80-300 V

Gen Sup Delay

The time for which the Generator voltage should, continuously be unhealthy to generate a fault condition

10Sec.

1-999 Sec.

CT Ratio

Available in models having provision for /5 CTs. Not required for Procom Make CTs

1

1-999

Generator O/C*

Max. permissible current, above this the Current is treated unhealthy & the Generator is stopped.

100A

1-999 (for /5 Cts)
1-199 A (for Procom CTs)

Gen O/C Delay

The time for which the Generator Current should, continuously be unhealthy to generate a fault condition

5Sec.

1-999 Sec.

Generator O/F*

Over frequency setting

65 Hz

40 - 80 Hz

Gen O/F Delay

Monitoring time for Over frequency

5 Sec

1-999 Sec.

Generator U/F*

Under frequency setting

45 Hz

40 - 80 Hz

Gen U/F Delay

Monitoring time for Under frequency

10 Sec

1-999 Sec.

 Download PDF File


MRM PROCOM PVT. LTD.
X


Contact Details
  • MRM PROCOM PVT. LTD.
    Faridabad, Harayana, India
  • Plot No. 20-21, Sector 59, Phase-2, Faridabad - 121004, Haryana, India
  • Phone : +918068092659
  • Send Inquiry   Send SMS
  • Mr. Pankaj Gupta (Director)
  • Mobile : +918068092659
MRM PROCOM PVT. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Ltd.